Skip to Content

EV charger labels: where engraved lamacoids go and when to use them

EV panels, load managers, disconnects, charger pedestals and emergency stops. Where engraved lamacoid labels go on an EV charging install, when to use them, and how to number chargers so the stall, the charger and the breaker all agree.

Guides7 min read
In short
  • An EV charging install is a chain: main switchboard, EV panel, load manager, disconnect, charger. Every link needs an engraved plate with its name and what feeds it.
  • Charger pedestals live outdoors, in parkades and in road salt. Engraved lamacoids stay readable there because the letters are cut into the plate, not printed on it.
  • Number every charger to match its circuit, so the person at the panel and the person at the stall are talking about the same unit.
  • Send the charger schedule as a spreadsheet. We engrave the whole site in Burlington, the same day, and ship Canada-wide.

Condo parkades, workplace lots, fleet yards and retail plazas across Ontario are adding chargers by the dozen. Each one adds circuits to a panel, a load manager to the electrical room and a pedestal or wall unit out in the parking area. When a charger trips at 7 a.m., someone has to find its breaker fast, and the person who installed it is long gone. This post covers where engraved lamacoid labels go on an EV charging install, when to use them, and what to engrave so the stall, the charger and the breaker all agree.

The EV charging power chain, with a plate on every box Power runs from main switchboard MDP-1 to EV panel EVP-1, then through load manager EVEMS-1 to charger circuits. A fused disconnect DISC-EV3 feeds DC fast charger EV-DC1, and branch circuits feed Level 2 chargers EV-P1-07 and EV-P1-08. Every box carries an engraved plate with its own name and the name of the box that feeds it. FROM THE SWITCHBOARD TO THE STALL every box in the chain carries its own name and its source ELECTRICAL ROOM PARKING LEVEL P1 MDP-1EVP-1EVEMS-1 main switchbdEV panelload manager 600V 3Ø208Y/120Vlimit 160A from UTILITYfrom MDP-1on EVP-1 DISC-EV3 DCFC disconnect from MDP-1 EV-P1-07EV-P1-08 Level 2Level 2 208V 40A208V 40A EVP-1 13/15EVP-1 14/16 EV-DC1 DC fast 600V 3Ø DISC-EV3 E-STOP Stand at any charger and trace it back to its breaker by reading plates. Example names and ratings. Use the names on your approved drawings.
The power chain on a typical parkade install. Every box from the switchboard to the charger carries its own name and where it is fed from, and the charger name includes its panel and circuit.

01Why EV chargers need proper labels

An EV charger is a large continuous load on a dedicated circuit. A Level 2 unit is typically fed at 208 V or 240 V, and a DC fast charger often takes three-phase power straight from the main switchboard. Many sites also run a load manager that shares one supply across a row of chargers, so a charger that seems "dead" may simply be waiting its turn.

That adds up to three questions every service call starts with: which charger is it, which breaker feeds it, and is it on a load manager? Engraved lamacoids answer all three on the equipment itself. Section 86 of the Canadian Electrical Code covers electric vehicle charging systems, and the code's general marking rules apply to the panels and disconnects behind them: marking has to be permanent, legible and clear about what the equipment does. Your drawings and the inspector set the exact wording.

02Where lamacoids go on an EV charging install

Walk a parkade install from the electrical room to the farthest stall and you pass the same handful of places. Each one gets a plate.

A parkade EV install with every plate location numbered Floor plan of parking level P1. Numbered markers show plate locations: 1 electrical room door, 2 EV panel EVP-1, 3 load manager EVEMS-1, 4 DC fast charger disconnect, 5 Level 2 charger pedestals, 6 wall-mounted chargers, 7 junction and pull boxes along the conduit run, 8 emergency stop at the DC fast charger. PARKING LEVEL P1 · WHERE THE PLATES GO numbers match the list below the plan ELEC ROOM P1 EVP-1EVEMSDISC DRIVE AISLE 0102030405060708 091011121314 EV-DC1 12345678 1 room door: ELEC ROOM P1 / EV EQUIPMENT 2 EV panel: name, voltage, fed from 3 load manager: name, panel, current limit 4 DC fast charger disconnect: what it feeds 5 pedestal chargers: ID + panel/circuit 6 wall chargers: ID + panel/circuit 7 junction and pull boxes: circuits inside 8 emergency stop at the fast charger
One parkade level, eight kinds of plate location. Example layout; the same list works for a surface lot, a fleet yard or a workplace garage.
EVP-1

EV panel

Panel ID on the door with its name, voltage and source, plus a matching directory. Engraved breaker tags make each charger circuit easy to find.

EVEMS-1

Load manager

Name the energy management system, the panel it controls and its current limit, so a service tech knows the chargers share a supply.

DISC-EV3

Disconnects

Every disconnect says what it serves. A fast charger fed from the switchboard gets a disconnect plate with the charger's name on it.

EV-P1-07

Charger pedestals and wall units

A charger ID that matches the panel schedule, the stall and the network app. Screw-mounted so it stays on through winters and car-wash spray.

JB-EV-2

Junction and pull boxes

Long conduit runs across a parkade pass through boxes overhead. A small plate listing the circuits inside saves a lot of ladder work.

EMERGENCY STOP

Emergency stops

Where a fast charger has an emergency stop, a red plate with white letters makes it obvious from across the lot.

03When to use engraved labels on chargers

Choose an engraved lamacoid for any label on an EV install that has to last as long as the equipment. That covers more than most people expect:

  • Outdoors and in parkades. Sun, road salt, slush and pressure washers are hard on printed labels. Engraved letters are cut into the plate and stay readable.
  • New installs before inspection and turnover. Label the panel, disconnects and chargers as part of the job, so the drawings, the directory and the equipment agree on day one.
  • Adding chargers to an existing building. Every new circuit changes a panel. Engraved breaker tags and an updated panel plate keep the old and new circuits clear.
  • Condo and multi-unit parkades. When each charger is tied to a unit or a stall, the plate carries that number, so the property manager, the electrician and the resident all point at the same charger.
  • Fleet depots and workplaces. Rows of identical chargers need IDs that match the charging network software, so a fault report names one unit.
  • Load-managed circuits. A short caution plate saying the chargers share a load manager answers the most common "it's not charging" call before anyone opens a panel.

04Numbering chargers so everyone agrees

The single most useful thing on an EV install is a charger name that ties the stall to the circuit. A good scheme carries the level, the charger number and, on the plate, the panel and breaker that feed it. Pick one format and use it on the drawings, the panel directory, the plates and the charging network app.

One charger name used in four places The name EV-P1-07 is broken into its parts: EV for the system, P1 for parking level 1, 07 for the stall. The same name appears on the panel directory against circuit 13/15, on the breaker tag, on the charger plate, and in the charging network app. ONE NAME, FOUR PLACES the charger ID ties the stall to the circuit EV-P1-07 EVsystem P1level 07stall PANEL DIRECTORY 11/13 EV-P1-06 13/15 EV-P1-07 14/16 EV-P1-08 BREAKER TAG EV-P1-07 on breaker 13/15 CHARGER PLATE EV-P1-07 EVP-1 CCT 13/15 on the pedestal NETWORK APP EV-P1-07 same ID in software
Example scheme: system, level, stall. The same ID on the directory, the breaker tag, the charger plate and the network app means a fault report points at exactly one charger and one breaker.

For colour, Black/White is the everyday choice for the EV panel, load manager and chargers. Many sites reserve Red/White for emergency stops and DANGER plates, and Yellow/Black for caution notes such as load-managed circuits. If the owner, the condo board or the charging network has a standard, we match it. Our colour guide covers the common pairs.

05What goes on an EV charger plate

Keep each plate short. The charger plate needs the ID big enough to read from the driving aisle, then the electrical details in smaller text for the person servicing it.

Anatomy of a 3 by 1.5 inch EV charger plate A black plate with white engraved letters, 3 inches by 1.5 inches, with two screw holes. Line one reads EV-P1-07 in large letters. Line two reads LEVEL 2 208V 1PH 40A. Line three reads FED FROM EVP-1 CCT 13/15. Callouts explain each line and the screw holes. ANATOMY OF A CHARGER PLATE 3" × 1.5" Black/White, screw mount · example wording EV-P1-07 LEVEL 2 · 208V 1PH 40A FED FROM EVP-1 CCT 13/15 IDreadable fromthe aisle TYPE + RATINGfrom drawings SOURCEpanel + breaker 3.0" SCREW HOLESstay put outdoors and through winters LETTERSID ≈ 1/2"details ≈ 3/16" FINISHengraved throughto the core
Example charger plate. The ID is large enough to read from the drive aisle; the rating and source are for the person with the panel key. Use the wording on your approved drawings.
Plate · sizeTypical wording
EV panel
4" × 2"
EVP-1 / 208Y/120V 3PH 4W 400A / FED FROM MDP-1
Load manager
4" × 1.5"
EVEMS-1 / CONTROLS EVP-1 / LIMIT 160A
DCFC disconnect
3" × 1.5"
DISC-EV3 / FEEDS EV-DC1 / 600V 3PH
Charger
3" × 1.5"
EV-P1-07 / LEVEL 2 208V 1PH 40A / FED FROM EVP-1 CCT 13/15
Breaker tag
to fit
EV-P1-07
Caution note
4" × 1.5"
CAUTION / CHARGERS SHARE LOAD MANAGER EVEMS-1 (Yellow/Black)

Not sure about letter size? Our post on lamacoid sizes matches letter height to reading distance.

06EV charging label facts worth knowing

  1. Section 86 is the EV section of the CEC. It covers electric vehicle charging systems. Each province adopts the code, in Ontario through the Ontario Electrical Safety Code, so check the edition in force where you work.
  2. Chargers are continuous loads. That is why a charger that draws 32 A typically sits on a 40 A circuit. Put the circuit rating on the plate, not just the charger's output.
  3. Load management changes the story. When an energy management system shares one supply across many chargers, the plates should say so. It explains slow charging before anyone suspects a fault.
  4. Fast chargers have their own source. DC fast chargers are often fed at three-phase from the main switchboard through a dedicated disconnect. Name the disconnect after the charger it feeds.
  5. Outdoor plates need screws. Adhesive alone can let go on cold, wet or textured pedestals. Screw holes or rivets keep the plate where it belongs.
  6. Engraving outlives print. The letters are cut through the top layer to the core colour, so UV and road salt do not wipe the name off.

07What to send when you order

DetailExample
WordingOne row per plate, from the panel schedule or charger list on the drawings
Charger IDsEV-P1-07, or the format your network app already uses
ColoursBlack/White for ID, Red/White for emergency stops, or the owner's standard
Size3" × 1.5" for chargers, 4" × 2" for panels, or match existing
MountingScrew holes for outdoor pedestals, adhesive or both indoors
QuantityBreaker tag plus charger plate for each circuit

A parkade with dozens of chargers is a spreadsheet job. Export the charger schedule and send it; our post on ordering from a spreadsheet shows how. For a handful of plates, design and price them in the Lamacoid Builder, or email lists to sales@llamacoids.ca. We engrave in Burlington, Ontario, the same day, and ship Canada-wide.

08Common questions

What labels does an EV charger install need?

The EV panel needs an ID plate and a circuit directory, each disconnect needs a plate saying what it serves, and each charger needs an ID that matches its circuit. Load managers, junction boxes and emergency stops should be labelled too. Your drawings and the inspector set the exact wording.

Which part of the electrical code covers EV chargers?

Section 86 of the Canadian Electrical Code covers electric vehicle charging systems. In Ontario the code is adopted as the Ontario Electrical Safety Code. The general marking rules for panels and disconnects apply as well.

How should EV chargers be numbered?

Use one format everywhere, such as system, parking level and stall: EV-P1-07. Put that ID on the charger, the breaker tag and the panel directory, and use the same ID in the charging network app.

What should an EV charger label say?

The charger ID, its type and circuit rating, and the panel and breaker that feed it, for example EV-P1-07 / LEVEL 2 208V 1PH 40A / FED FROM EVP-1 CCT 13/15.

Do engraved lamacoids work outdoors on charger pedestals?

Yes. The letters are engraved into the plate, so sun, road salt and pressure washing do not wipe them off. Order screw holes for outdoor pedestals so the plate stays mounted through winter.

Can you label a whole parkade of chargers at once?

Yes. Send the charger schedule as a spreadsheet with the wording, colour and size for each plate. We engrave it in Burlington the same day and ship Canada-wide.

Label the whole parkade

Send the charger schedule as a spreadsheet and we will quote it, or design a few plates in the builder.

Burlington, Ontario · Same-day turnaround · Ships Canada-wide · 289-275-9572